Integrated planetary rotary actuator · Model 1 highlights

70 Nm peak planetary robot actuator, 36:1 ratio: MGA-PJ-43-15-36

Model 1 combines a 36:1 planetary reduction with 20 Nm rated torque, 70 Nm under “Peak torque (>3 s)” and 117 rpm peak speed. A steel output plate can be reviewed for an impact-loaded mechanism. Specify the impact load path and mounting geometry when requesting the option drawing.

MGA-PJ-43-15-36 integrated planetary joint actuator, three-quarter product view on a white background.
MGA-PJ-43-15-36 product view. The image is used as a visual reference; confirm the exact configuration before design release.

Model 1 summary

Start with the published torque, speed, mass, and ratio

These highlights describe Model 1. Compare the configuration tables below with the load cycle, mounting and controller requirements.

Peak torque (>3 s)
70 Nm
Peak speed
117 RPM
Weight
530 g
Reduction ratio
36

Standard model and model-specific options

Start with the listed planetary configuration and its model-specific options. Describe the interface or function that needs to change so the build, drawing and applicable limits can be reviewed together.

  • Standard configuration has no through-bore and does not support a brake.
  • Standard communication supports CAN bus; EtherCAT/CAN FD can be customized.
  • The standard configuration has no water-resistance protection. Contact sales before ordering if IP54 is required.
  • A custom steel output plate is described for high-impact applications such as ankle joints.

Request a configuration review

Describe the interface or function you would like to adjust, along with the application requirements. We can check whether a listed option or another configuration is available for this model. The exact build, drawing, and applicable limits need confirmation before an order.

  • Required continuous torque, peak torque, peak duration, and repetition rate
  • Output speed, acceleration, reversal, impact, and duty cycle
  • Mounting face, bolt pattern, shaft/bore, cable route, and external loads
  • Supply voltage, control mode, communication, feedback, brake, and protection requirements
Ask about this model's options

MGA-PJ-43-15-36 technical specifications

The listed build is Model 1. Request a configuration review if the duty or interfaces need to change. Unspecified cells are marked “Not specified.”

Motor electrical
ParameterUnitModel 1Model 2
Operating voltageV12-60Not specified
Rated voltageV48Not specified
Rated torqueNm20Not specified
Rated speedRPM80Not specified
Rated currentA(rms)7Not specified
Peak torque (>3 s)Nm70Not specified
Peak speedRPM117Not specified
Peak currentA(rms)25Not specified
Torque constantNm/A2.93Not specified
Back-EMF constantVrms/KrpmNot specifiedNot specified
Speed constantrpm/V87Not specified
Motor constantNm/√WNot specifiedNot specified
Electromechanical time constantmsNot specifiedNot specified
Electrical time constantmsNot specifiedNot specified
Pole pairs—14Not specified
Winding connection—StarNot specified
Phase resistanceΩ0.9Not specified
Phase inductancemH0.41Not specified
Mechanical
ParameterUnitModel 1Model 2
Reduction ratio—36Not specified
Reducer backlashArcmin10Not specified
Output bearing—Crossed-roller bearingNot specified
Backdrive torqueNm0.7Not specified
Rotational inertiag.cm²Not specifiedNot specified
Weightg530Not specified
Axial loadkN4.8Not specified
Radial loadkN2.1Not specified
Control and interface
ParameterUnitModel 1Model 2
Control bandwidthHz2000Not specified
Communication—CANNot specified
Encoder type—Mechanical dual encoderNot specified
Encoder resolutionbit14Not specified
CAN interface—XT30(2+2)PB-MNot specified
USB interface—SH1.0-4PNot specified
Power interface—XT30(2+2)PB-MNot specified
Control modes—Servo mode; Speed mode; Torque mode; Force-position hybrid modeNot specified
Protection functions—Overvoltage protection; Overcurrent protection; Overtemperature protectionNot specified
Environment
ParameterUnitModel 1Model 2
Duty type—S2Not specified
Ingress protection—IP40Not specified
Cooling method—IC410Not specified
Ambient operating temperature—-20℃~50℃Not specified
Insulation class—FNot specified
Dielectric strength—500V 1kHz 1A 1msNot specified
Insulation resistance—100MΩ 20℃Not specified
Noise—60dB/1.0mNot specified
Temperature sensor—NTC MF52B 103F3950Not specified

All data are provided for U= 48 V and T= 25°C, unless otherwise specified. Specifications for different voltage levels or other operating limits, and corresponding simulation models, are available upon request.

Have a torque-speed profile or mounting drawing?

Send it with the duty cycle and controller requirements for a model-specific engineering review.

Start an Engineering Review

01 · Screen the duty

Match torque and speed over time

Compare rated and peak values with the actual motion profile, including peak duration, repetition, acceleration, and thermal conditions. Do not size from peak torque alone.

02 · Check interfaces

Resolve the mechanical and electrical stack

Compare the original drawing with the mating parts, loads, cable route, connectors, supply, communication protocol, and feedback requirements.

03 · Confirm the build

Match the build and acceptance conditions

Confirm the selected Model 1/Model 2 configuration, current drawing revision, option content, test conditions, and validation evidence before freezing a design.

Original drawing and motor performance map

Check mounting and cable clearances in the original 2D drawing. Review the torque, speed, power, current and efficiency map with the selected configuration; confirm curve identities and test conditions before using it for controller or thermal sizing. Open either image for a larger view.

MGA-PJ-43-15-36 original 2D technical drawing showing dimensioned mounting and housing views; source image used unchanged.
Original 2D drawing reproduced unchanged. Confirm revision, tolerances, and mating interfaces before production use.
MGA-PJ-43-15-36 source motor performance map with torque in Nm, speed in rpm, power in W, current in A, and efficiency in percent.
Source motor performance map. Curve labels/configuration are not identified in the graphic; confirm which configuration and operating limits apply before design closure.

Ask about a 3D STEP model

STEP availability is not confirmed for this model. Email us with the public SKU and requested configuration so we can check.

Ask about STEP availability

Compare related rotary actuator configurations

Compare the rated duty, ratio and interfaces of these related models before choosing a configuration for quotation.

Make the first review specific

Connect the published specifications with your mechanism. Share the fixed interfaces and open design questions so the next review can focus on the required configuration and prototype decisions.

  • Target continuous and peak output torque, including duration and cycle rate
  • Required output speed, acceleration, reversals, and duty type
  • Mounting drawing, mating parts, bore/shaft, cable path, and external loads
  • Supply voltage, drive/controller, protocol, encoder, brake, and protection needs
  • Ambient temperature, contamination, shock, noise, and service-life targets
  • Prototype or production stage, quantity range, destination, and validation plan

Add a torque measurement requirement

Use MGA-PJ-43-15-36 as the actuator reference for an output-torque sensing review. Define the sensor location, load path, bearing support, mounting and readout before selecting the combined configuration.

MGA-PJ-43-15-36 frequently asked questions

What is needed to review the steel output-plate option?

Send the mounting geometry, impact direction, load magnitude and repetition, plus the proposed acceptance test. The steel plate is a customization direction; its exact geometry and impact capability need a configuration-specific review.

Do dual encoders mean the actuator includes a torque sensor?

Dual encoders provide motion feedback. Check their locations and interfaces for the selected configuration. A separate output-torque measurement needs its own sensor arrangement, load path and applicable calibration records. An engineered elastic element with position sensing can also measure torque; the label “dual encoder” alone does not establish that design.

Is encoder resolution the same as positioning accuracy?

Model 1 lists 14 bit encoder resolution. Resolution describes measurement increments. Installed positioning accuracy also depends on encoder performance, mounting, the transmission and control system. Use the configuration and conditions of a position test rather than interpreting a bit count as an angular-accuracy guarantee.

Can I request MGA-PJ-43-15-36 together with torque sensing?

Use MGA-PJ-43-15-36 as the actuator reference and share the required torque measurement point, mounting drawing, operating loads and readout. Review the combined mechanical and measurement configuration as a development project, with its sensor, mounting and acceptance scope defined together.

What torque and speed does MGA-PJ-43-15-36 list?

Model 1 lists 20 Nm rated torque and 70 Nm under “Peak torque (>3 s),” with 80 RPM rated speed and 117 RPM peak speed. Check the torque-speed profile and repetition of each load against the operating conditions below. These figures are separate parameters, not a simultaneous operating point.

What do Model 1 and Model 2 mean?

The specifications describe Model 1. Model 2 cells are unspecified; request a separate configuration review if the listed build needs to change.

What duty-cycle information is needed for selection?

Send torque and speed over time, peak duration and repetition, acceleration, dwell and cooling conditions. Include mounting loads and the controller interface so the rated and peak values can be reviewed against the complete cycle.

Which motor-performance-map curves apply to each configuration?

Use the map to frame the torque, speed, power, current and efficiency review. Request confirmation of the curve identities, configuration and test conditions before using a curve for controller or thermal sizing.

Application & assembly review

Review MGA-PJ-43-15-36 against your load, interface, and operating envelope

Share the torque-speed cycle, peak duration, mounting drawing and controller requirements. Include the prototype stage, quantity range and acceptance priorities to define the next configuration review.

Bring a sketch, selected components or the open interface questions. Use the review to define the assembly scope and next development step.